BMC BiPAP GII Bi-Level CPAP Machine With Humidifier

Bi-level Positive Airway Pressure With Ti Min/Ti-Max
Packaging Accessories
1.Main Device (On the left of the machine with LCD screen)
2.Humidifier (On the right of the machine with water tank)
3.Face Mask or Nasal Mask
4.Spo2 Kit
5.Air Tubing (183cm)
6.SD card (4 GB)
7.Filters For Air cleaning
8.Carrying Case (Packed in items and covered by carton box)
9.Power Cord (Connect to adapter)
10.AC/DC Power Adapter (Local Voltage)
11.User Manual (Local Language)
12.Quick Operation Manual (Local Language)
TECHNICAL SPECIFICATIONS
Dimensions: 170 × 196 × 118 mm
290 × 196 × 134 mm (with humidifier)
Weight: < 1.5 kg
< 2.5 kg (with humidifier)
Product Use, Transport, and Storage
Operation | Transport and Storage | |
Temperature: | 5°C to 35°C (41°F to 95°F) | -25°C to 70°C (-13°F to 158°F) |
Humidity: | 15% to 93% Non-condensing | 15% to 93% Non-condensing |
Atmospheric Pressure: | 760 to 1060 hPa | 760 to 1060 hPa |
Mode of Operation
Continuous
Model Comparison
Work Mode | Pressure | LCD Screen | |
T-20S | CPAP, S | 4-20 cm H2O | 2.4 inches |
T-20A: | CPAP, S, AUTO | ||
T-20T | CPAP, S, T, S/T | ||
T-25S | CPAP, S | 4-25 cm H2O | 3.5 inches |
T-25A | CPAP, S, AUTO | ||
T-25T | CPAP, S, T, S/T | ||
T-30T | CPAP, S, T, S/T | 4-30 cm H2O | 3.5 inches |
SD Card
With a capacity≥ 2G, the SD card can record patient data and fault information. Furthermore, the language pack stored on the SD card enables you to change the language of the device.
AC Power Consumption
100 – 240 V AC, 50/60 Hz, 2.0 A max
Type of Protection Against Electric Shock
Class II Equipment
Degree of Protection Against Electric Shock
Type BF Applied Part
Degree of Protection Against Ingress of Water
IP22
Pressure Range
4 to 30 hPa (in 0.5 hPa increments), ≤ 30 hPa for CPAP mode, ≤ 30 hPa for the rest modes under single fault conditions.
Pressure Display Accuracy
± (0.5 hPa + 4%)
Ramp
The ramp time ranges from 0 to 60 minutes
Sound Pressure Level
<30 dB, when the device is working at the pressure of 10 hPa.
Sound Power Level
<38 dB, when the device is working at the pressure of 10 hPa.
SpO2
Range: 0-100%
The margin of error for SpO2 between 70% and 100% is ±3%. No strict accuracy requirements for SpO2 below 70%.
Pulse Rate
Range: 40-240 bpm
The margin of Error: ± 3%
Wavelengths
Red: 663 nanometers
Infrared: 890 nanometers
Maximal Optical Output Power
Less than 1.5 mW maximum average
Tube
Length: 6 ft. (1.83m)
Humidifier Performance
Humidity Output: No less than 10 mg H2O/L
Environmental Conditions: Maximum airflow, 35°C, 15% relative humidity
ADVANTAGE



The color LCD screen will be convenient for you to see the data in the process of treatment. With an exquisite control knob, BMC RESmart GII Series brings you unsurpassed operational experience.



Depending on the location of the region to choose a different setting, the machine will make the pressure compensation accordingly and automatically.

APPEARANCE


Buttons & Details

Mute Button: Press this button to mute the alert. Hold it for 3s,check iCode.
Knob: Start treatment and adjust device settings. Indicate the power supply statute.
Button Ramp: Enable the Ramp feature.
Outlet Air: Deliver humidified air to the patient; connect to the air tubing.
Observation Window: Observe the water level in the water chamber.
Water Inlet: The water inlet is in the bottom of the water storage tank.

Breath Waveform: On the screen is the treatment of pressure and airflow waveform.
Monitoring Parameters: All kinds of monitoring parameters are displayed on the screen.
Ventilation Mode: Numerical values of specific parameters in the current mode.Patient Menu

| Option | Description |
SpO2 | Optional, please tell customer service if necessary | |
Humidifier | Let the inhaled air more humid, more comfortable | |
Ramp Time | Time to use the machine to enter treatment pressure | |
Mask Type | Select the type of mask you are equipped with | |
iCode | Scan iCode, access to treatment data | |
Brightness | The brightness of the machine screen is adjustable |
*Notice: The patient’s menu will not cover all the machine functions and options, more settings included in the doctor’s menu.
Doctor Menu

| Option | Description |
Mode | CPAP,AUTO/S,S | |
Max Ramp | Take reference of the average time for patients to fall asleep | |
Ramp P | The pressure being delivered while patients are awake | |
IPAP/EPAP | Set an expiratory pressure and suction pressure to assist in breathing and breathing | |
Ti Min/Max | The setting defines the patient’s longest and shortest breathing time, and is more secure | |
Rise Time | The time it takes for the device to change from EPAP to IPAP. You can adjust this time for your comfort |
*Notice: We seriously recommend you follow your doctor’s clinical advice before changing settings.
How to choose masks:






Specification: BMC BiPAP GII Bi-Level CPAP Machine With Humidifier
|
User Reviews
Be the first to review “BMC BiPAP GII Bi-Level CPAP Machine With Humidifier”

$1,213.65



There are no reviews yet.